Biosafety Cabinet Class II A2

It is the most popular safety cabinet with a slant shutter so workability has been improved. It conforms to JIS standards and is a type approved model of JACA.

 

  • It is JIS standard (JIS K 3800) conforming model.
  • JACA (corporation) Japan Air Cleaning Association type certification acquisition product.
  • Adopting a slant shutter, workability has been improved.
  • The fan is a new design that can extend the life of the HEPA filter.
  • The operation panel can display the inflow wind speed and air supply wind speed and can grasp the operating condition.
  • In addition to this, we have various IIA 2 type safety cabinets, such as NSF / ANSI 49-2012 approved NSF standards, and specialized models for radiopharmaceuticals and dispensing rooms / pharmacies.

 

 JIS standard (K3800: 2009) / JACA type certification ( K3800:2009)
Model
BHC-1307ⅡA2(series model 1007、1607、1907)
Dust collect efficiency
More than 99.99% at 0.3μm
Dust collect efficiency
Supply/Exhaust: HEPA filter(test item)
Processing air volume
Front opening dimension 200mm Air supply:18.6m³/min、Exhaust:10.7m³/min
Front opening dimension 250mm Air supply:18.8m³/min、Exhaust:10.7m³/min
Wind speed in the room
Front opening size 200mm : 0.43m/sec±0.025m/sec
Front opening size 200 mm: 0.43 m / sec ± 0.025 m / sec

Front opening dimension 250 mm: 0.44 m / sec ± 0.025 m / sec

Front suction wind speed
Front opening size 200 mm : 0.69m/sec±0.025m/sec
Front opening dimension 250 mm : 0.55m/sec±0.025m/sec
Power supply
AC100V 1φ 50/60Hz
Power consumption
Abt 330W(fan + lighting operation)
Weight
Abt 320Kg
External dimension
W1500×D792×H2040mm [In-line size W1300×D600×H640]
The smallest move-in size
W1500×D730×H1970mm(in each size leave the remainder is 20mm)
Structure
Body:powder coated steel、working room, handrails:stainless steel
Step:anodize aluminium
Lighting
Light 11W×3LED
Sterilizing
15W×2 pcs(inventer)
Option
Exhaust room(include buffer φ250)、pressure gauge、automatic nozzle、other

JIS Standard

Model
BHC-1007ⅡA2 / BHC-1607ⅡA2 / BHC-1907ⅡA2 / BHC-1307ⅡA2-LE(Exhaust type)
Dust collect efficiency
More than 99.99% at 0.3μm
Filter
Supply/Exhaust: HEPA filter(scanning test product)
Supply air volume (m³/min)
Front opening size 200mm : abt 14.3 / abt 19.4 / abt 25.3 / abt 14.4
Front opening size 250mm :abt 14.4 /abt 20.0 / abt 25.6 / ―
Exhaust air volume(m³/min)
Front opening size 200mm :abt 8.3 /abt 12.2 /abt 14.8 / abt 8.6
Front opening size 250mm :abt 8.3 /abt 12.2 / abt 14.8 / ―
Wind speed in the room (m/sec)
Front opening size 200mm
:abt 0.43±0.025 / abt 0.37±0.025 /abt 0.40±0.025 / abt 0.33±0.025
Front opening size 250mm
:abt 0.44±0.025 / abt 0.38±0.025 / abt 0.41±0.025 / ―
Blowing wind speed to front(m/sec)
Front opening size 200mm
:abt 0.69±0.025 / abt 0.64±0.025 / abt 0.65±0.025 /abt 0.55±0.025
Front opening size 250mm
: abt 0.55±0.025 /abt  0.51±0.025 / abt 0.52±0.025 / ―
Power supply
AC100V 1φ 50/60Hz
Power consumption (W)
abt 250 / abt 490 /abt  560 /abt 330
Equipment power (VA)
abt 350 / abt 620 / abt 700 / abt 450
Blower (台)
LFN-10×1 / LFN-10×2 / LFN-10×2 / LFN-10×1
LED light (W)
abt 8×3 / abt 14×3 /abt  17×3 / abt 14W×3
Sterilizing lamp (W)
abt 15×2 / abt 15×2 /abt  15×2 / abt 11×3
Weight (kg)
abt 270 / abt 410 /abt 480 / abt 320
Smallest move-in size (mm)
W1200×D730×H1970 / W1800×D730×H1970 / W2100×D730×H1970 / W1500×D730×H1970
Structure
Body:powder coated steel、working room:SUS304
Option
Exhaust room(include buffer φ250)、pressure gauge、automatic nozzle、other

 

 Biosafety Cabinet Class ⅡA2(Model:BHC-1307ⅡA2)(E-Catalogue)

AIRTECH_BHC-1307_2A2_leaflet-1_top

 

ĐỂ LẠI THÔNG TIN ĐỂ ĐƯỢC CHÚNG TÔI BÁO GIÁ TỐT
Click Here