Ceiling clean air system for operating room (two-speed type)

The requirement for sterility in recent years has undergone dramatic changes. This is due to the progress of technology (aeraulics) in general and the progress of related fields and the installation of air treatment systems.

The criteria for certifying the equipment in the operating room accordingly must be changed.

Experts recommend using a unidirectional ventilation system with multiple air flows rather than a diffused airflow system.

The ultra-clean level of the guaranteed airflow is maintained even in the event that medical personnel travel back and forth or into or out of a protected area.

The results obtained during the counting of dust particles near the site of the incision, in terms of asepsis, the unidirectional airflow is much better than the turbulent airflow.

  • Can adjust wind speed from 0.25 to 0.5 m / s.
  • Pressure drop from 8 to 25 mm CE.
  • Supply air through 2-layer stretch fabric.
  • Air inlet at the end of the ceiling through 2 regulating valves of 2 separate air supply areas.
  • LED lights are integrated on the bottom of the stretch fabric.
  • Linked to the ceiling by threaded rods
  • DOP sockets for air pressure differential measurement to control filtration.
  • Optional LED lighting system with 24V (standard IP65) (adjustable)
  • Hepa H14 air filter, size 610x1220x70 mm * 12 pieces.
  • Fiberglass filter.
  • Perforated protective face plate is painted Epoxy.
  • The aluminum frame is sealed by gaskets in the air supply position.
  • 99.999% DOP efficiency.
  • Size: 3342x3342x500 mm

To respond to Lucerne University of Applied Technology in Switzerland, ATV has developed a generation of ceiling-cleaning air cleaners for 2-speed type operating rooms to match the standard operating room SICC 99-3 standard.

It is a vertical flow from the ceiling down to ensure a clean level of ISO 5 according to ISO 14 644 for operating rooms that require high sterility such as orthopedic surgery room. The cavity compartment (air vent compartment) is made of galvanized steel with powder coating outside or covered with white epoxy or stainless steel. This air vent compartment is fitted with Hepa H14 filter (dust filtration efficiency up to 99.995% according to EN 1822 standard).

The system is equipped with anti-touch side shields, capable of removing most of the dust particles (through the crank in particular).

Airflow rate (from 025 to 0.5 m / s) can be set in 2 separate areas (in the center and peripheral areas) to increase the comfort of health workers (during prolonged surgeries) ), restricting the penetration of biological dust particles in the protected area and dispersing vapors generated during surgery

To get the right amount of wind, it is necessary to take into account the specific characteristics of the dust level and microbiological cleanliness of each area and object. In addition, the following parameters need to be defined:

  • Air-discharge method
  • Air filtration efficiency
  • Wind flow and conditions (humidity and temperature) of supply air, intake air, fresh air and outlet air.
  • Noise level allows users to work in comfortable conditions.

Despite the fact that there are many separate methods available to choose the type of air conditioner installed, one must agree that the clean air filters used will be very effective in removing micro organisms (such as bacteria, viruses, molds, yeast, etc.) use inert gases to move, multiply and grow.

Airtech The Long is an expert in the field of clean air, will provide for you:

  • Specific advices for building solutions.
  • A strong commitment to the selection of good quality air filtration equipment.
  • Assist in providing technical personnel with expertise in the acceptance of equipment.
  • Technical training.
  • Remote support to ensure trouble-free operation and use of the device